Products and Equipment

The Energy Product Business Unit is mainly engaged in production and sales of magnetic switches, molded case circuit breakers, medium and low voltage switchboards and power distribution equipment. Acting for many well-known foreign manufacturer of various products such as low voltage switches, high, medium and low voltage power distribution equipment and generators. We have the most complete series of models and are able to provide complete pre-sales and after-sales services from system planning and design, production, manufacturing, construction and maintenance.

Power Device

Low-voltage switch products are important components in power facilities and an indispensable basic product for industrial development. Through continuous research and development, we have complete products models which are suitable wide range of applications to be flexibly selected according to customer needs. Low voltage switch series products feature excellent electrical characteristics, precise and sensitive action, low impact, long life and high safety, and comply with CNS, IEC, NEMA, VDE regulations; have obtained CSA, UL, TUV certificates. 

Learn More

Switchgear

The Production & Research Division of Energy Products Business Unit  is mainly engaged in production and sales of medium and low voltage switchboards and power distribution equipment. It has various high, medium and low voltage power distribution equipment and has the most complete series of models and are able to provide complete pre-sales and after-sales services from system planning and design, production, manufacturing, construction and maintenance. 
High and low voltage switchboard and control equipment are developed through continuous research and innovation for the applicability and safety of power distribution systems in factories, public facilities and urban buildings. Except for the best service features of artistic appearance, high quality and high reliability, it is popular among users. 

Learn More

Diesel engine generator

TECO diesel engine generator has superior performance and solid structure which can operate continuously for long period. Europe, US, Japan and Korea brand engines are used. After the generator and diesel engine are directly coupled through a flexible connector, they are combined on a strong shock-proof channel iron base. The whole set of equipment can operate normally in the working environment where the temperature is 0℃~40℃, the altitude is 1000 meters, and the relative humidity is below 95%. All rotating parts are covered by shields, and are equipped with automatic protection and warning devices such as high water temperature, low oil pressure, overspeed, and starting overrun, which can automatically alarm and shutdown to ensure personnel safety.

Learn More

Gas Insulated Switchger

"氣體絕緣開關設備"即Gas Insulated Switchgear,簡稱GIS。乃由斷路器、隔離開關、接地開關、比流器、比壓器、匯流排、套管、絕緣支持器、控制機構及電纜連接裝置等所組合,並將帶電部分封於SF6氣體充填且充分接地之包封外殼內。

Learn More

Product introduction video

RCS節能開關DEMO BOX操作說明

RCS節能開關DEMO BOX操作說明:

nRCS 是配合壁上開關或插座使用的裝置,主要應用為於控制家庭照明總開關,旅館出入門總開關… 等。
n人員出門前可透過屋內壁上開關或是外部連網一鍵關閉室內所有的照明電源或部分插座等,不重要的負載 (如燈具或待機家電),無須逐一關閉所有開關,可達節能效果及防止電線走火的機率。

ATSH家用電源自動切換開關--測試操作

東元ATSH電源自動切換開關主要應用方式作為主電源(正常電源)與備用電源之切換,當正常電源發生斷電或不規則時會即時輸出信號,系統會由原本的正常供電電源自動切換至緊急備用電源;待正常電源恢復供電時,系統會在由備用電源自動切換至正常電源系統,繼續供電,以確保負載端之各項運作不致中斷。

Downloads

Designed for customer service, product information such as catalog, certification, dimension and product specifications for electromagnetic contactors, switches, no-fuse breakers are available for easily inquire, browse and download.

Learn More

Industrial application category

Magnetic switches & Low voltage switch series

Application market: power systems, pumps, cranes, fans, air conditioning equipment, elevators, control motors, heating and cooling air conditioners, ventilation equipment, refrigeration equipment.

Thermal overload relay

Applications: Buildings, offices, residences, hospitals, elevators, lifts, switchboards, air conditioning systems, motor protection circuits for automated machinery.

Molded Case Circuit Breakers
Application places: line protection, main switch and shunt switch of the distribution system of apartments, houses, buildings and factories.
Earth Leakage Circuit Breakers
Application places: line protection of residential, buildings, factories, outdoor facilities, power distribution system, leakage detection, leakage detection of electrical equipment (water heaters, water dispensers), main switches, shunt switches, street lights, traffic signs, outdoor distribution boxes, amusement parks facility.

Recommended Products

Product Q&A

  • What is the structure of TECO ATSH?
    • The structure of TECO ATSH: three sets of terminals
      1. A set of normal power input terminals. (AL and AN)
      2. A set of backup power input terminals. (BL and BN)
      3. The other set is the output terminals of the load power. (L and N). Do not connect them incorrectly.
      *Power window for ATSH: 
             Green: Indicates that the normal power (mains or solar power) is supplying
      Red: Indicates that the backup power (generator power or mains) is supplying
      *ATSH have DIP switch function for automatic/manual switching
  • What are the functions of automatic/manual DIP switch of TECO ATSH M1 type?
    • TECO ATSH model M1 automatic/manual switching DIP switch function description: 
      1. The DIP switch is set at automatic: 
        If both power sources exist at the same time, it is mandatory to use the normal power source (mains power or solar power) to supply power.
      2. The DIP switch is set at manual: 
          If both power sources exist at the same time, it is mandatory to use the backup power source (generator or mains power) to supply power.
      At this time, the DIP switch must be pulled back to the automatic position to return to the normal power supply (mains power or solar power) state.
       
  • The features of TECO ATSH?
    • 1. This product is magnetic contactor type (MC) A.T.S. with mechanical and electrical interlock function. 
      2. Single coil design, when the power is supplied normally, the MC switch does not act to avoid energy consumption.
      3. The mechanical window display is linked with the MC switch, which displays the power supply source without misjudgment
  • Operation precautions of TECO ATSH
    • 1. Before operation, please confirm whether the input voltage meets the demand.
      2. The common power side and the standby power side should not be reversely connected
      3. The output capacity is specified, please do not increase equipment capacity.